Why my hot tub is not heating up and how to fix it

It is incredibly frustrating in order to pull back the cover simply to realize my hot tub is not heating up despite being switched on all night. You're ready for a relaxing soak to soothe muscle tissue, but rather, the water feels more like the lukewarm puddle than a steaming hot tub. Before you begin mourning your weekend plans or fearing a huge repair bill, take a deep breath. Most associated with the time, the particular reason a hot tub stops obtaining hot is something relatively simple that you can troubleshoot yourself.

There are the handful of common culprits behind a cold tub, which range from dirty filters in order to air bubbles trapped in the water lines. Let's walk by means of the procedure for shape out why your own water is wintry and the way to get that will temperature climbing once again.

Check the particular obvious stuff first

Sometimes we all overlook the simplest things because we're worried about the particular expensive parts. Begin by checking your control panel. Does it have power? If the particular screen is blank, you may have a tripped breaker. Go in order to your main electric panel or the sub-panel near the particular tub if ever the GFCI breaker has visited off. If it provides, flip it in return. In the event that it trips once again immediately, you've obtained a short a place, which usually points towards the heater or even the pump.

If the section is on, look at the temperature setting. I know it sounds ridiculous, but sometimes someone accidentally bumps the buttons or puts the tub into "Economy" or "Sleep" mode. In these types of modes, the heating unit only kicks upon during filtration series or keeps the water significantly cooler than your target temperature. Switch it in return to "Standard" or even "Ready" mode and see if the heater light opens.

The filtration system is usually the particular villain

When you've been wondering why my hot tub is not heating up , the very first physical component you should check is the filter. This is the cause associated with about 80% of heating issues. Hot tubs need a specific amount of drinking water flowing through the heater to perform safely. In case your filters are clogged with body oils, lotions, or debris, the flow decreases.

When the detectors detect that the particular water isn't shifting fast enough, these people shut the heater off to prevent it from reaching extreme temperatures and melting the internal components. This particular is often accompanied by an error program code around the screen like "FLO, " "FL, " or "Low Flow. "

Do this: turn off the power, take the filters out totally, then turn the particular tub back upon. If the heater starts working without the filters in place, you've found your trouble. It's time to give those filters a deep soak in the chemical cleaner or even, if they're greater than a year old, simply toss them and buy new ones.

Resetting the particular high-limit switch

Hot tubs are equipped with the safety device known as a high-limit change. Consider it like a dedicated outlet breaker for that heating unit. If the drinking water gets too hot—or if the sensors think it's too hot due to the fact of a short-term flow issue—this change will "trip" plus cut power to the heater.

You are able to usually discover a small red reset button upon the side associated with the heater housing or in the control box. Guarantee the power is off just before you go poking around in the cabinet. Give that will button a firm push. If you listen to a click, that might have been the particular problem. Turn the power back upon and see in the event that the tub starts drawing heat. Simply keep in mind that if it trips again, it's an indicator that your own water is in fact getting too hot or the change itself is faltering.

Dealing along with air locks

Did you recently drain and refill your spa? In the event that so, and now my hot tub is not heating up , you likely have got an air lock. This happens whenever a big bubble of air will get trapped within the plumbing, usually right inside the pump. Because the pump is seeking to push air rather than water, no blood circulation happens, and the heater won't participate.

You'll generally hear the push humming or gurgling if this is the situation. To fix it, a person can try "burping" the tub. Loosen the union nut on the discharge side of the particular pump just enough in order to let the surroundings hiss out. Once water starts trickling out steadily, tighten up it back up. Usually, the water pump will prime by itself, the flow may return, and the particular heater will punch back into equipment.

Is the particular heater element actually dead?

When the pump is shifting water beautifully, the particular filters are clean, and there are usually no error rules, but the water stays cold, the heating unit element itself may be "dry fired" or simply worn-out. Over time, the calcium in your own water can create up on the element (like the inside of an old kettle), or poor water chemistry can corrode it until this cracks.

If you're comfortable utilizing a multimeter, you can test the element for "continuity. " With the power off, disconnect the particular wires from the particular heater terminals and check the resistance. In case the meter displays "O. L. " or infinite opposition, the element is "open" and requires to be changed. Replacing just the element is very much cheaper than changing the entire stainless steel heater assembly, though it's the bit more of a finicky job.

Thermostats and sensors

Your own hot tub depends on two major sensors: the temp sensor (which tells the tub how hot the drinking water is) and the particular high-limit sensor (the safety backup). In case either of such goes wonky, the tub won't heat.

Sometimes a messfühler will go poor and tell the pc that the water is already 110 degrees when it's actually 60. The computer thinks, "Hey, I'm plenty hot, " and not becomes the heater upon. If you get a weird temperature reading on your display screen that doesn't match how the water senses, you've likely got a faulty messfühler. These are usually pretty cheap and simple to plug to the primary circuit board, but they can become a slight pain in order to thread through the plumbing.

Examine your water levels

It noises basic, but I've seen it happen dozens of times. In the event that your water level falls too low—maybe the particular kids were splashing a lot or you had a small leak—the skimmer might start sucking within air. Once air flow gets into the system, the pump manages to lose its prime, the particular flow drops, and the heater shuts lower. Always make sure your water level is from least halfway up the skimmer opening. It's an easy fix that doesn't cost a dime.

When to get in touch with the professionals

I'm all for a good DO-IT-YOURSELF project, but right now there are times whenever you just have to admit defeat. When you've checked the particular filters, reset the breakers, and confirmed the flow, yet you're still looking at a cold tub, the issue may be the primary circuit board.

If you see burned spots on the board or smell that distinct "fried electronics" scent, it's probably time in order to call a tech. Messing with 240v electricity can be harmful if you don't know exactly exactly what you're doing. Furthermore, if you suspect a major leak inside the equipment region is causing a brief, it's better to have a pro appearance at it before you end up leading to more damage.

Wrapping things up

It's definitely a bummer whenever my hot tub is not heating up , but don't let it wreck your week. Start with the fundamentals: clear the filters, check for air hair, and make certain the breaker hasn't tripped. More often than not, it's just a matter of restricted drinking water flow. Keeping your water chemistry balanced and your filters clean is the best way in order to prevent this from happening again within the future. Once you get that high temperature back, you'll value that first soak even more!